1. Capable of controlling ultra high-pressure liquefied hydrogen (Control range: ultra high-pressure of up to 100 MPa, ultra low temperature of down to -253°C)

2. High-Flowrate (Cv value of 1.0)

Design Pressure: 100Mpa

Fluid Temperature: -253°C to +50°C

Ambient Temperature: -40°C to +50°C 

Body Materials: SUH660

Ultra Low Temperature Valves For Liquefied Hydrogen